GYF axial flow fan application:
GYF axial flow fan can be used not only for fire-fighting and smoke exhaust of various buildings, but also for smoke and air exhaust of high-rise buildings, general buildings, underground garages, mine culverts, etc. For example, underground warehouses are usually used for exhaust ventilation, Turn to large air volume for smoke exhaust when necessary.
GYF axial fan consists of five main components:
1. Impeller
2. Motor
3. Internal circulation wind impeller
4. Guide vane, inner cylinder, guide tube hole
5. Outer cylinder.
GYF axial flow fan parameters:
machine number | Speed | Condition | Air volume | Total pressure | Power | Exit dry sound | Shell noise | Weight |
4-Ⅰ | 2900 | 1 | 6162 | 372 | 1.1 Y90S-2 | 82 | 70 | 61 |
4.5-I | 2900 | 1 | 8677 | 436 | 1.5 Y90L-2 | 83 | 73 | 70 |
5-Ⅰ | 2900 | 1 | 10857 | 419 | 2.2 Y100L-2 | 86 | 74 | 78 |
5.5-Ⅰ | 2900 | 1 | 12710 | 402 | 4 Y112M-2 | 86 | 75 | 108 |
6-Ⅰ | 2900 | 1 | 16734 | 514 | 5.5 Y132S1-2 |